Totalflow EIE
Important: The correct version of the Totalflow API (tcidll.dll or tcidll64.dll) must be installed in order for the Totalflow EIE to operate properly. For more information, see Totalflow API.
The Totalflow EIE supports four generations of Totalflow flow computers (FC) and/or remote controllers (RC) as well as other ABB API-supported devices. Generations supported are Totalflow G1, G2, G3, and G4. Totalflow G3 and G4 devices were once known as XSeries devices.
The CygNet interface to the ABB API is templated, which means you can define device template files to suit specific needs. User-defined device template files allow you to match Totalflow device register configurations, to add new register-based data groups, and to retrieve device-level data from an ABB trend. Sample device template files for Totalflow G1, G2, G3, and G4 devices are available from CygNet; they include representative register-based data groups. Many Totalflow device configurations are possible; because of this, create a new device template file for each device model and/or configuration.
The CygNet Totalflow EIE provides several ways to retrieve current volume data. Each current volume data group element serves a specific purpose and retrieves a unique kind of data. Familiarize yourself with each before choosing how you to retrieve current volume data.
Specifications
The following table lists and describes EIE specifications.
|
Manufacturer |
ABB |
|
Protocol(s) |
ABB API |
|
Model(s) |
Totalflow G1 devices Totalflow G2 devices (6400 and 6700) Totalflow G3 devices Totalflow G4 devices Other models supported by the ABB API |
|
Required Files |
CxDdsToFloEditors.dll UisToFloDriver.dll or UisToFloDriver64.dll tcidll.dll or tcidll64.dll (*See Totalflow API) |
|
FMS Import File |
The following file is required for importing data from a Totalflow laptop file into FMS:
For more information, see Installing CygNet Measurement and Import: Totalflow Laptop File in the CygNet Measurement section. |
|
Sample Templates |
Totalflow_Api.dtf (for G1 and other ABB API-supported devices) Totalflow_6400.dtf (for G2 devices) Totalflow_6700.dtf (for G2 devices) Totalflow_G3.dtf Totalflow_G4.dtf |
|
ToFlo |
|
|
Cryout Support |
Yes |
|
FMS Support |
Yes, using FMS EFM data items. Note: In cases where both GMR and FMS support was previously available, CygNet Measurement now provides data support using FMS data items only. If you were previously using GMR data items, you must update to use FMS data items. Update options are provided as part of your software upgrade procedure. |
|
Listen Mode |
No |
|
64-bit Support |
Yes. See 64-bit Device Drivers. |
For more information, see sample device template files and manufacturer documentation.
More:
UIS Command Component Parameters
Current Volume Data Group Elements
FMS Configuration Data Group Mapping
FMS Daily PM History Data Group Mapping
FMS Hourly PM History Data Group Mapping